6KVA/5.4KW Long Run On-line Smart UPS, Tower
- On-Line UPS
- Pure sine wave
Model: MP 6k H
- Warranty: 2 years
- A manager will call you to confirm the order
- Installation and setup by Squad IT if you need it
Specifications
- Autonomy Working Period
- Long Run - requires batteries
- volt-ampere
- 6000 VA
- Active power
- 5400 W
- Number of Phases
- 1
- Nominal input voltage range
- 110 V - 286 V
- Nominal output voltage
- 230 V
- Frequency range
- 40 Hz - 70 Hz
- Output frequency
- 50 ±0.1% Hz
- Integrated battery capacity
- -
- Parallel Redundancy
- -
- With Transformer
- -
- Waveform
- Pure Sine Wave
- Efficiency
- 93.5 %
- Bypass
- +
- Automatic restart on AC recovery
- +
- Generator compatible
- +
- Cold start function
- +
- Self-Diagnosis
- +
- LCD panel for option
- +
- USB Port for management
- +
- SNMP card slot
- +
- Power terminal
- -
- Number of outlets
- 1 pc
- Outlet type
- -
- Operating temperature
- 0 °C - 40 °C
- Weight
- 12 kg
Description
MP 6k H requires 192/216/240 V DC, which is achieved by connecting 16/18/20 12V batteries in series.
Kstar's MP H series uninterruptible power supplies (UPS) are high-reliability devices with input and output voltage isolation. This feature ensures the protection of connected equipment from damage caused by fluctuations in electrical parameters within the network. In the event of a power outage, these UPS systems seamlessly switch to backup power without delay. External batteries with capacities of up to 200 amps can be connected to the UPS, providing extended autonomous operation for connected devices. These UPS systems are ideal for providing long-lasting and reliable power to critical equipment such as data centers, medical devices, advanced security systems, and more. Functional capabilities Double ConversionPure Sine WaveZero Transfer Time to Backup PowerLCDInterface: EPO, RS232, USB, SNMP/Dry Contact SlotGenerator CompatibilitySelf-Diagnostic Function
Conditions for Warranty Coverage
Installation must be performed by a qualified electrical engineer in compliance with the guidelines provided in the official installation manual.
The device must be connected to a grounding system that meets the standards defined by Georgian legislation.
The UPS must be protected from industrial and natural dust, with temperature and humidity levels maintained as specified in the technical documentation.
If you are using a generator with a distorted output signal, it is important to enable generator mode on the uninterruptible power supply (UPS).