KA
  1. Home
  2. Products
  3. Energy Supply
  4. On-Line UPS
  5. 2KVA/1.8KW On-line Smart UPS, Tower 4x9AH battery
KSTARSKU: SQ00750

2KVA/1.8KW On-line Smart UPS, Tower 4x9AH battery

  • On-Line UPS
  • Pure sine wave

Model: MP 2k S

1 241.70 ₾
On order — we will confirm the lead time

Offer us your price

2KVA/1.8KW On-line Smart UPS, Tower 4x9AH battery
Our price is 1 241.70 ₾. Tell us what you would pay and a manager will get back to you.

  • Warranty: 2 years
  • A manager will call you to confirm the order
  • Installation and setup by Squad IT if you need it

Specifications

Autonomy Working Period
Short Run - with AGM batteries
volt-ampere
2000 VA
Active power
1800 W
Number of Phases
1
Nominal input voltage range
110 V - 300 V
Nominal output voltage
230 V
Frequency range
40 Hz - 70 Hz
Output frequency
50 ±0.1% Hz
Integrated battery capacity
4x 9 Ah
Parallel Redundancy
-
With Transformer
-
Waveform
Pure Sine Wave
Efficiency
90 %
Bypass
+
Automatic restart on AC recovery
+
Generator compatible
+
Cold start function
+
Self-Diagnosis
+
LCD panel for option
+
USB Port for management
+
SNMP card slot
+
Power terminal
-
Number of outlets
2 pc
Outlet type
3, იგივე F (გერმანული სტილი)
Operating temperature
0 °C - 40 °C
Weight
19.5 kg

Description

Kstar's MP S series uninterruptible power supplies (UPS) are high-reliability devices that feature input and output voltage isolation. This design ensures the protection of connected equipment from damage caused by fluctuations in electrical parameters within the network. In the event of a power outage, these UPS systems seamlessly switch to backup power, provided by integrated batteries, without any delay. These UPS systems are ideal for powering critical and sensitive equipment such as medical devices, data centers, advanced security systems, and more. Functional capabilities Double ConversionPure Sine WaveZero Transfer Time to Backup PowerLCDInterface: EPO, RS232, USB, SNMP/Dry Contact SlotGenerator CompatibilitySelf-Diagnostic FunctionNote The UPS system itself comes with a 24-month warranty, the integrated batteries are covered by a 12-month warranty When connecting high-class online UPS systems to the network, it is essential to ensure proper phase and neutral alignment. If the UPS emits an audible alarm after being powered on, first adjust the switch, reconnect to the power grid, and try restarting the device.

If you are using a generator with a distorted output signal, it is important to enable generator mode on the uninterruptible power supply (UPS).